文章来源:http://www.trcables.com/ 作者:上海嗨润 发布时间::2018-01-17 14:04 浏览次数:次
IEC 60092-376 | IEC 60092-351 |
IEC 60092-359 | IEC 60332-1 |
IEC 60332-3-22 | IEC 60754-1,2 |
IEC 61034-1,2 | NEK 606:2004 |
VG 95218 part 29? |
l???? Conductors: Circular stranded copper wire to IEC 60228 class 2.
l???? Insulation: XLPE.
l???? Filler: Water blocking fillers, if required.
l???? Bedding: Halogen free thermoplastic compound.
l???? Metal Screen: Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor, PETP wrapping tape will be applied over the bedding, if required.
l???? Water Blocking Elements: Water blocking tape and strings for providing longitudinal water tightness.
l???? Inner Sheath: Halogen free thermoplastic compound, SHF1, coloured grey.
l???? Outer Sheath: Polyurethane for providing transversal water tightness, PE is optional,but can not meet low smoke standard.
Nominal Cross Section Area | mm2 | 2.5 |
Maximum Resistant@20˚C | O/km | 7.41 |
Continuous Current Rating@45˚C2 Core | A | 26 |
Short Circuit Current 1s | A | 360 |
Operating Voltage | V | 250 |
Construction |
Nominal |
Nominal |
Nominal |
Nominal |
Nominal |
Nominal Weight kg/km |
2×1×2.5 |
0.7 |
1.1 |
1.2 |
1.0 |
12.0±2 |
189 |